    Refractometer Calibration Standards

    catalog number
    price
    Quantity
     
    info
    catalog number: 90-401
    price: 
     
    Quantity: 
    ADD TO BAG
    catalog number: 90-402
    price: 
     
    Quantity: 
    ADD TO BAG
    catalog number: 90-403
    price: 
     
    Quantity: 
    ADD TO BAG
    catalog number: 90-404
    price: 
     
    Quantity: 
    ADD TO BAG
    catalog number: 90-405
    price: 
     
    Quantity: 
    ADD TO BAG
    catalog number: 90-406
    price: 
     
    Quantity: 
    ADD TO BAG
    catalog number: 90-407
    price: 
     
    Quantity: 
    ADD TO BAG
    catalog number: 90-408
    price: 
     
    Quantity: 
    ADD TO BAG
    catalog number: 90-418
    price: 
     
    Quantity: 
    ADD TO BAG

    A refractometer is a device that measures how light bends—or refracts—when it passes through a substance. This refraction correlates with the concentration of solutes in liquids. Whether it's sugar in juice (Brix), saline in water, or chemicals in coolants—refractometers tell you how much "stuff" is in your liquid.

    What Are Calibration Standards?

    Calibration standards are reference solutions or materials with known refractive indices. By comparing your refractometer’s reading to the standard’s known value, you can adjust it to ensure accurate measurements.

    Importance of Accurate Calibration

    Ensuring Measurement Precision

    Precise measurements ensure consistency, whether you're brewing craft beer or manufacturing pharmaceuticals.

    Compliance With Industry Regulations

    Many industries—like pharma, food, and biotech—require documented, validated calibration for audits and compliance.

    Preventing Costly Errors in Production

    Wrong sugar levels in juice? Off-concentration in eye drops? These aren’t just mistakes—they’re business and safety risks.

    Certified Reference Materials for Refractometers & Polarimeters

    Ensure the accuracy of your lab instrumentation with premium Certified Reference Materials (CRMs) by Bellingham + Stanley, a trusted name in analytical calibration. Whether you're working in food production, pharmaceuticals, petrochemicals, or beverage industries, our extensive CRM solutions are designed to support reliable performance and compliance with international standards.

    Why Use CRMs?

    Regular instrument verification is essential—not just for quality control but also for maintaining optimal operational efficiency. All of our CRMs are manufactured to stringent standards and certified under ISO/IEC 17025:2017 by UKAS, the United Kingdom's national accreditation body and a signatory of the ILAC Mutual Recognition Arrangement.

    Our CRM Product Range Includes:

    ✅ Water-Based Low Brix Solutions

    Ideal for calibrating instruments measuring lower Brix values.

    ✅ High-Value Oil-Based Standards

    Designed for industries requiring verification across a wide refractive index spectrum.

    ✅ Sucrose Calibration Solutions

    Convenient and ready-to-use for instruments with automatic temperature compensation (ATC).

    ✅ Quartz Control Plates for Polarimetry

    Engineered for precise angular and sugar scale calibration, traceable to PTB standards.

    AG Calibration Fluids (Water-Based)

    Perfect for applications requiring low-end °Brix or refractive index validation. Available in cost-effective multipacks with long shelf life (12 months minimum).

    Refractive Index & °Brix Examples:

    • AG2.5 → RI: 1.33659 | °Brix: 2.50

    • AG15 → RI: 1.35568 | °Brix: 15.00

    • AG40 → RI: 1.39986 | °Brix: 40.00

    Certified by UKAS | ±0.000037 RI Uncertainty | ICUMSA/NIST Traceable

    Calibration Oils

    Used primarily for instruments operating across wide refractive ranges—such as in the edible oil sector. Due to their temperature sensitivity, we recommend precise temperature control during calibration.

    Examples:

    • BSLP → RI: 1.46607 | °Brix: 70.25

    • BSDD → RI: 1.55900 | °Brix: n/a

    Certified by UKAS | Up to ±0.000103 RI Uncertainty | ICUMSA/NIST Traceable

    Industry-Specific Multi-Packs

    Mixed value multipacks are ideal for service engineers and QA teams. These ready-to-use kits simplify instrument verification and are available for:

    • Soda Industry

    • Beverage Manufacturing

    • Juice Processing

    • Pharmaceutical & Chemical Sectors

    • Petrochemical Applications

    Each pack contains 5 x 5ml bottles, disposable pipettes, and UKAS calibration certificates.

    Sucrose Calibration Solutions

    Our sucrose-based standards are convenient, easy to use, and optimized for refractometers with ATC. Supplied in 15ml dropper bottles, these are perfect for reducing contamination risks and increasing calibration accuracy.

    Shelf Life: 6 Weeks | Storage: Refrigerate (5°C) | Certified by UKAS

    Available Brix values range from 0% to 60%, with corresponding refractive index values provided.

    Aqueous Urea Calibration Solutions for DEF Testing

    For ISO 22241 compliance in Diesel Exhaust Fluid (DEF) applications, we offer a reliable CRM with a refractive index equivalent to 32.5% urea.

    • BS-AUS | RI: 1.38290 | Shelf Life: 12 months

    • Supplied in 5ml glass vials (single or 5-pack)

    Certified by UKAS | ±0.000034 RI Uncertainty

    Quartz Control Plates (QCP) for Polarimeters

    Manufactured with precision for verifying polarimeter performance. Available in single values or sets, each plate is optionally certified with traceability to PTB.

    Available Angular & ISS Values:

    • ±30° | ±10° | ±5° | 15° | 34° | 50°

    • Set configurations available upon request

    UKAS Certified | Best Uncertainty: ±0.017°Z | Re-certification recommended

    142949 90-4XX SERIES Media/Uploads/90-4XX_SERIES-OUT(1).webp Refractometer Calibration Standards <p>A refractometer is a device that measures how light bends—or refracts—when it passes through a substance. This refraction correlates with the <b>concentration</b> of solutes in liquids. Whether it's sugar in juice (Brix), saline in water, or chemicals in coolants—refractometers tell you how much "stuff" is in your liquid.</p><h2><b><span style="color: rgb(0, 32, 96);">What Are Calibration Standards?</span></b></h2><p>Calibration standards are <b>reference solutions</b> or materials with known refractive indices. By comparing your refractometer’s reading to the standard’s known value, you can adjust it to ensure accurate measurements.</p><h2><b><span style="color: rgb(0, 32, 96);">Importance of Accurate Calibration</span></b></h2><p><b>Ensuring Measurement Precision</b></p><p>Precise measurements ensure consistency, whether you're brewing craft beer or manufacturing pharmaceuticals.</p><p><b>Compliance With Industry Regulations</b></p><p>Many industries—like pharma, food, and biotech—require documented, validated calibration for audits and compliance.</p><p><b>Preventing Costly Errors in Production</b></p><p>Wrong sugar levels in juice? Off-concentration in eye drops? These aren’t just mistakes—they’re business and safety risks.</p><h2 data-section-id="psaqv3" data-start="282" data-end="352"><strong data-start="285" data-end="352"><span style="color: rgb(0, 32, 96);">Certified Reference Materials for Refractometers &amp; Polarimeters</span></strong></h2> <p data-start="354" data-end="740">Ensure the accuracy of your lab instrumentation with premium Certified Reference Materials (CRMs) by <strong data-start="455" data-end="479">Bellingham + Stanley</strong>, a trusted name in analytical calibration. Whether you're working in food production, pharmaceuticals, petrochemicals, or beverage industries, our extensive CRM solutions are designed to support reliable performance and compliance with international standards.</p> <h3 data-section-id="eizlg3" data-start="747" data-end="768"><strong data-start="751" data-end="768">Why Use CRMs?</strong></h3> <p data-start="770" data-end="1125">Regular instrument verification is essential—not just for quality control but also for maintaining optimal operational efficiency. All of our CRMs are manufactured to stringent standards and certified under <strong data-start="977" data-end="999">ISO/IEC 17025:2017</strong> by <strong data-start="1003" data-end="1011">UKAS</strong>, the United Kingdom's national accreditation body and a signatory of the <strong data-start="1085" data-end="1124">ILAC Mutual Recognition Arrangement</strong>.</p> <h3 data-section-id="1j3716b" data-start="1132" data-end="1171"><strong data-start="1136" data-end="1171">Our CRM Product Range Includes:</strong></h3> <h4 data-start="1173" data-end="1212">✅ Water-Based Low Brix Solutions</h4> <p data-start="1213" data-end="1275">Ideal for calibrating instruments measuring lower Brix values.</p> <h4 data-start="1277" data-end="1316">✅ High-Value Oil-Based Standards</h4> <p data-start="1317" data-end="1404">Designed for industries requiring verification across a wide refractive index spectrum.</p> <h4 data-start="1406" data-end="1444">✅ Sucrose Calibration Solutions</h4> <p data-start="1445" data-end="1535">Convenient and ready-to-use for instruments with automatic temperature compensation (ATC).</p> <h4 data-start="1537" data-end="1583">✅ Quartz Control Plates for Polarimetry</h4> <p data-start="1584" data-end="1671">Engineered for precise angular and sugar scale calibration, traceable to PTB standards.</p> <h3 data-section-id="144r077" data-start="1678" data-end="1721"><strong data-start="1682" data-end="1721">AG Calibration Fluids (Water-Based)</strong></h3> <p data-start="1723" data-end="1884">Perfect for applications requiring low-end °Brix or refractive index validation. Available in cost-effective multipacks with long shelf life (12 months minimum).</p> <p data-start="1886" data-end="1924"><strong data-start="1886" data-end="1924">Refractive Index &amp; °Brix Examples:</strong></p> <ul data-start="1925" data-end="2038"> <li data-start="1925" data-end="1962"> <p data-start="1927" data-end="1962">AG2.5 → RI: 1.33659 | °Brix: 2.50</p> </li> <li data-start="1963" data-end="2000"> <p data-start="1965" data-end="2000">AG15 → RI: 1.35568 | °Brix: 15.00</p> </li> <li data-start="2001" data-end="2038"> <p data-start="2003" data-end="2038">AG40 → RI: 1.39986 | °Brix: 40.00</p> </li> </ul> <blockquote data-start="2040" data-end="2110"> <p data-start="2042" data-end="2110">Certified by UKAS | ±0.000037 RI Uncertainty | ICUMSA/NIST Traceable</p> </blockquote> <h3 data-section-id="13xm8t1" data-start="2117" data-end="2141"><strong data-start="2121" data-end="2141">Calibration Oils</strong></h3> <p data-start="2143" data-end="2346">Used primarily for instruments operating across wide refractive ranges—such as in the edible oil sector. Due to their temperature sensitivity, we recommend precise temperature control during calibration.</p> <p data-start="2348" data-end="2361"><strong data-start="2348" data-end="2361">Examples:</strong></p> <ul data-start="2362" data-end="2435"> <li data-start="2362" data-end="2399"> <p data-start="2364" data-end="2399">BSLP → RI: 1.46607 | °Brix: 70.25</p> </li> <li data-start="2400" data-end="2435"> <p data-start="2402" data-end="2435">BSDD → RI: 1.55900 | °Brix: n/a</p> </li> </ul> <blockquote data-start="2437" data-end="2513"> <p data-start="2439" data-end="2513">Certified by UKAS | Up to ±0.000103 RI Uncertainty | ICUMSA/NIST Traceable</p> </blockquote> <h3 data-section-id="1or9tr" data-start="2520" data-end="2557"><strong data-start="2524" data-end="2557">Industry-Specific Multi-Packs</strong></h3> <p data-start="2559" data-end="2707">Mixed value multipacks are ideal for service engineers and QA teams. These ready-to-use kits simplify instrument verification and are available for:</p> <ul data-start="2708" data-end="2852"> <li data-start="2708" data-end="2727"> <p data-start="2710" data-end="2727"><strong data-start="2710" data-end="2727">Soda Industry</strong></p> </li> <li data-start="2728" data-end="2756"> <p data-start="2730" data-end="2756"><strong data-start="2730" data-end="2756">Beverage Manufacturing</strong></p> </li> <li data-start="2757" data-end="2779"> <p data-start="2759" data-end="2779"><strong data-start="2759" data-end="2779">Juice Processing</strong></p> </li> <li data-start="2780" data-end="2819"> <p data-start="2782" data-end="2819"><strong data-start="2782" data-end="2819">Pharmaceutical &amp; Chemical Sectors</strong></p> </li> <li data-start="2820" data-end="2852"> <p data-start="2822" data-end="2852"><strong data-start="2822" data-end="2852">Petrochemical Applications</strong></p> </li> </ul> <p data-start="2854" data-end="2949">Each pack contains <strong data-start="2873" data-end="2892">5 x 5ml bottles</strong>, disposable pipettes, and UKAS calibration certificates.</p> <h3 data-section-id="665geg" data-start="2956" data-end="2993"><strong data-start="2960" data-end="2993">Sucrose Calibration Solutions</strong></h3> <p data-start="2995" data-end="3220">Our sucrose-based standards are convenient, easy to use, and optimized for refractometers with ATC. Supplied in <strong data-start="3107" data-end="3131">15ml dropper bottles</strong>, these are perfect for reducing contamination risks and increasing calibration accuracy.</p> <blockquote data-start="3222" data-end="3292"> <p data-start="3224" data-end="3292">Shelf Life: 6 Weeks | Storage: Refrigerate (5°C) | Certified by UKAS</p> </blockquote> <p data-start="3294" data-end="3394">Available Brix values range from <strong data-start="3327" data-end="3340">0% to 60%</strong>, with corresponding refractive index values provided.</p> <h3 data-section-id="1nyw97q" data-start="3401" data-end="3459"><strong data-start="3405" data-end="3459">Aqueous Urea Calibration Solutions for DEF Testing</strong></h3> <p data-start="3461" data-end="3607">For ISO 22241 compliance in Diesel Exhaust Fluid (DEF) applications, we offer a reliable CRM with a refractive index equivalent to <strong data-start="3592" data-end="3606">32.5% urea</strong>.</p> <ul data-start="3609" data-end="3710"> <li data-start="3609" data-end="3661"> <p data-start="3611" data-end="3661"><strong data-start="3611" data-end="3621">BS-AUS</strong> | RI: 1.38290 | Shelf Life: 12 months</p> </li> <li data-start="3662" data-end="3710"> <p data-start="3664" data-end="3710">Supplied in 5ml glass vials (single or 5-pack)</p> </li> </ul> <blockquote data-start="3712" data-end="3758"> <p data-start="3714" data-end="3758">Certified by UKAS | ±0.000034 RI Uncertainty</p> </blockquote> <h3 data-section-id="iqzory" data-start="3765" data-end="3817"><strong data-start="3769" data-end="3817">Quartz Control Plates (QCP) for Polarimeters</strong></h3> <p data-start="3819" data-end="3982">Manufactured with precision for verifying polarimeter performance. Available in single values or sets, each plate is optionally certified with traceability to PTB.</p> <p data-start="3984" data-end="4019"><strong data-start="3984" data-end="4019">Available Angular &amp; ISS Values:</strong></p> <ul data-start="4020" data-end="4103"> <li data-start="4020" data-end="4059"> <p data-start="4022" data-end="4059">±30° | ±10° | ±5° | 15° | 34° | 50°</p> </li> <li data-start="4060" data-end="4103"> <p data-start="4062" data-end="4103">Set configurations available upon request</p> </li> </ul> <blockquote data-start="4105" data-end="4181"> <p data-start="4107" data-end="4181">UKAS Certified | Best Uncertainty: ±0.017°Z | Re-certification recommended</p> </blockquote> 0 0 refractometer-calibration-standards 0 0 0
    blogs

    BLOGS

    ABOUT US

    ABOUT US

    CONTACT US

    CONTACT US

    SERVICE CENTER

    SERVICE CENTER

    • ABOUT
    • |
    • PRODUCTS
    • |
    • CATALOGS
    • |
    • SUPPORT
    • |
    • SERVICE CENTER
    • |
    • CUSTOMERS
    • |
    • TERMS
    • |
    • Privacy Policy
    • |
    • FAQ
    • |
    • BLOGS

    [email protected], + 972-3-5595252
    ISRAEL: Hagavish 3 Holon
    UK: Cavendish House Parkway, Harlow Business Park, Harlow, CM19 5QF

    • Bsmart בניית אתרים
    • SAP
    altImg

    • Fully Supported on Chromee*
    • Color Blind Adjusted
    • Heavy Vision Adjusted
    • Regular Display
    • Access Keys MenuAlt + 0
    • Stop Motion
    • Remove Underline Links
    • Press Keys For View Resize
    • Ctrl + Larger
    • Ctrl - Smaller
    • Ctrl 0 Reset Size
    • Enable Disable Keyboard Focusing
    • Reset All To Defualt

    Access Keys

    • Enable/Disable This MenuAlt + 0
    • Skip To Main MenuAlt + 1
    • Skip To Main ContentAlt + 2
    • דלג למפת אתר מונגשת Alt + Shift + 3
    • SearchAlt + 4
    • Contact PageAlt + 7
    • דלג למפת העמוד Alt+5
    • Skip To HomepageAlt + h
    • Skip To Accessibilty MenuAlt + m

    *Firefox users: Use Alt + Shiftnumber

    In order to move between elements, Press - Tabkey, To backtrack press, - Shift + Tab

  • Skip To Main Menu
  • Skip To Main Content
  • Skip To Accessbilty Menu
  • This website uses cookies for the purpose of ongoing and proper operation in accordance with the privacy policy