    Ultrapure water system, Low TOC (tap water inlet)

    Low TOC Model
    Standard configuration: Main body (Including 1 set of cartridge)+15 liters pressure tank
    Feed water requirements: Tap water, temperature:5-45°C,pressure:1.0-4.0Kgf/cm2
    Output(25°C)*: 30 liters/hour
    *The value will be influenced by temperature and feed water´s quality.
    Flow rate: Up to 2 liters/minute(with pressure tank)
    Pure water outlet: 2: reverse osmosis water, ultrapure water
    Ultrapure water quality:
    ====================
    Resistivity(25°C): 18.2MΩ.cm
    TOC*: <3ppb
    Bacteria: <0.01cfu/ml
    Particle(>0.1µm): <1/ml
    RO water quality :
    ====================
    Ion rejection rate: 97%-99% (new RO membrane)
    Organic rejection rate: >99%, when MW>200 Dalton
    Particles and bacteria rejection rate : >99%
    READ MORE >
      CATALOG NUMBER: WPL-RO-UP-30-UV-V2
      $0
      • TECHNICAL DATA
      • FUNCTIONS
      • DESCRIPTION
      • ACCESSORIES
      • VIDEOS
      • DOCUMENTATION
      • DOWNLOAD
      • REQUEST A QUOTE
      Low TOC Model
      Standard configuration: Main body (Including 1 set of cartridge)+15 liters pressure tank
      Feed water requirements: Tap water, temperature:5-45°C,pressure:1.0-4.0Kgf/cm2
      Output(25°C)*: 30 liters/hour
      *The value will be influenced by temperature and feed water´s quality.
      Flow rate: Up to 2 liters/minute(with pressure tank)
      Pure water outlet: 2: reverse osmosis water, ultrapure water
      Ultrapure water quality:
      ====================
      Resistivity(25°C): 18.2MΩ.cm
      TOC*: <3ppb
      Bacteria: <0.01cfu/ml
      Particle(>0.1µm): <1/ml
      RO water quality :
      ====================
      Ion rejection rate: 97%-99% (new RO membrane)
      Organic rejection rate: >99%, when MW>200 Dalton
      Particles and bacteria rejection rate : >99%

      Operation Manual

       

      CE

       

      TECHNICAL DATA

        Operation Manual
        WPL-RO-UP-30-UV_OPR.pdf
        CE
        WPL-RO-UP-30-UV_CE.pdf

      FUNCTIONS

      DESCRIPTION

      Low TOC Model
      Standard configuration: Main body (Including 1 set of cartridge)+15 liters pressure tank
      Feed water requirements: Tap water, temperature:5-45°C,pressure:1.0-4.0Kgf/cm2
      Output(25°C)*: 30 liters/hour
      *The value will be influenced by temperature and feed water´s quality.
      Flow rate: Up to 2 liters/minute(with pressure tank)
      Pure water outlet: 2: reverse osmosis water, ultrapure water
      Ultrapure water quality:
      ====================
      Resistivity(25°C): 18.2MΩ.cm
      TOC*: <3ppb
      Bacteria: <0.01cfu/ml
      Particle(>0.1µm): <1/ml
      RO water quality :
      ====================
      Ion rejection rate: 97%-99% (new RO membrane)
      Organic rejection rate: >99%, when MW>200 Dalton
      Particles and bacteria rejection rate : >99%

      ACCESSORIES

      VIDEOS

      DOCUMENTATION

      Operation Manual

       

      CE

       

      DOWNLOAD

      REQUEST A QUOTE

      Specifications

      Theory

      blogs

      BLOGS

      ABOUT US

      ABOUT US

      CONTACT US

      CONTACT US

      SERVICE CENTER

      SERVICE CENTER

      • ABOUT
      • |
      • PRODUCTS
      • |
      • CATALOGS
      • |
      • SUPPORT
      • |
      • SERVICE CENTER
      • |
      • CUSTOMERS
      • |
      • TERMS
      • |
      • Privacy Policy
      • |
      • FAQ
      • |
      • BLOGS

      [email protected], + 972-3-5595252
      ISRAEL: Hagavish 3 Holon
      UK: Cavendish House Parkway, Harlow Business Park, Harlow, CM19 5QF

      • Bsmart בניית אתרים
      • SAP
      altImg

      • Fully Supported on Chromee*
      • Color Blind Adjusted
      • Heavy Vision Adjusted
      • Regular Display
      • Access Keys MenuAlt + 0
      • Stop Motion
      • Remove Underline Links
      • Press Keys For View Resize
      • Ctrl + Larger
      • Ctrl - Smaller
      • Ctrl 0 Reset Size
      • Enable Disable Keyboard Focusing
      • Reset All To Defualt

      Access Keys

      • Enable/Disable This MenuAlt + 0
      • Skip To Main MenuAlt + 1
      • Skip To Main ContentAlt + 2
      • דלג למפת אתר מונגשת Alt + Shift + 3
      • SearchAlt + 4
      • Contact PageAlt + 7
      • דלג למפת העמוד Alt+5
      • Skip To HomepageAlt + h
      • Skip To Accessibilty MenuAlt + m

      *Firefox users: Use Alt + Shiftnumber

      In order to move between elements, Press - Tabkey, To backtrack press, - Shift + Tab

    • Skip To Main Menu
    • Skip To Main Content
    • Skip To Accessbilty Menu
    • This website uses cookies for the purpose of ongoing and proper operation in accordance with the privacy policy