    single channel multi-mode 2 syringe pump (140ml)

    • Syringe size: 10 ul – 140 ml;
    • Work mode: infusion, withdraw, infusion/withdraw, withdraw/infusion, continuous mode;
    • Channel number: 2;
    • Stroke of pump: 140 mm;
    • pusher advance per microstep: 0.156 um/ustep;
    • linear speed: 1 um/min – 150 mm/min;
    • Linear resolution: 1 um/min;
    • Linear travel accuracy: error <± 0.35% (>30% of pump stroke);
    • Linear force: maximum rated: > 20KGF;
    • Thrust regulation: 1-100% arbitrary adjustable.
    • Syringe selection: built-in main manufacturers, the main model syringe to choose;Can use custom syringe, direct input syringe size& diameter;
    • Flow calibration: through the calibration procedure to obtain more accurate fluid volume;
    • Display: 4.3 -inch color LCD, 480 * 272 resolution, color 65 k;With screen display and transfusion volume, quantity of liquid, flow, operation direction, syringe specification, etc.;Animation display operation status;
    • Operation mode: touch screen + button;
    • Power-off memory: storing the running parameters automatically.;
    • Other features: pause and stop;The sound tip;The lock parameters;Fast forward and retreat quickly;
    • State signal output: 1 road stop state, 1 state road direction;
    • Control signal input: 1 way down along the priming, 1 way down along the trigger to stop;
    • communication interface: RS485, MODBUS protocol;
    • Applicable power: AC100-240 v / 20 w;
    • working temperature: 5 to 40 ℃;
    • Relative humidity: < 80% RH;
    • Dimension: 290 * 205 * 180 mm
    • Weight: 4.4 kg
    READ MORE >
      CATALOG NUMBER: SYP-02-02
      $0
      • TECHNICAL DATA
      • FUNCTIONS
      • DESCRIPTION
      • ACCESSORIES
      • VIDEOS
      • DOCUMENTATION
      • DOWNLOAD
      • REQUEST A QUOTE
      • Syringe size: 10 ul – 140 ml;
      • Work mode: infusion, withdraw, infusion/withdraw, withdraw/infusion, continuous mode;
      • Channel number: 2;
      • Stroke of pump: 140 mm;
      • pusher advance per microstep: 0.156 um/ustep;
      • linear speed: 1 um/min – 150 mm/min;
      • Linear resolution: 1 um/min;
      • Linear travel accuracy: error <± 0.35% (>30% of pump stroke);
      • Linear force: maximum rated: > 20KGF;
      • Thrust regulation: 1-100% arbitrary adjustable.
      • Syringe selection: built-in main manufacturers, the main model syringe to choose;Can use custom syringe, direct input syringe size& diameter;
      • Flow calibration: through the calibration procedure to obtain more accurate fluid volume;
      • Display: 4.3 -inch color LCD, 480 * 272 resolution, color 65 k;With screen display and transfusion volume, quantity of liquid, flow, operation direction, syringe specification, etc.;Animation display operation status;
      • Operation mode: touch screen + button;
      • Power-off memory: storing the running parameters automatically.;
      • Other features: pause and stop;The sound tip;The lock parameters;Fast forward and retreat quickly;
      • State signal output: 1 road stop state, 1 state road direction;
      • Control signal input: 1 way down along the priming, 1 way down along the trigger to stop;
      • communication interface: RS485, MODBUS protocol;
      • Applicable power: AC100-240 v / 20 w;
      • working temperature: 5 to 40 ℃;
      • Relative humidity: < 80% RH;
      • Dimension: 290 * 205 * 180 mm
      • Weight: 4.4 kg

      TECHNICAL DATA

        FUNCTIONS

        DESCRIPTION

        • Syringe size: 10 ul – 140 ml;
        • Work mode: infusion, withdraw, infusion/withdraw, withdraw/infusion, continuous mode;
        • Channel number: 2;
        • Stroke of pump: 140 mm;
        • pusher advance per microstep: 0.156 um/ustep;
        • linear speed: 1 um/min – 150 mm/min;
        • Linear resolution: 1 um/min;
        • Linear travel accuracy: error <± 0.35% (>30% of pump stroke);
        • Linear force: maximum rated: > 20KGF;
        • Thrust regulation: 1-100% arbitrary adjustable.
        • Syringe selection: built-in main manufacturers, the main model syringe to choose;Can use custom syringe, direct input syringe size& diameter;
        • Flow calibration: through the calibration procedure to obtain more accurate fluid volume;
        • Display: 4.3 -inch color LCD, 480 * 272 resolution, color 65 k;With screen display and transfusion volume, quantity of liquid, flow, operation direction, syringe specification, etc.;Animation display operation status;
        • Operation mode: touch screen + button;
        • Power-off memory: storing the running parameters automatically.;
        • Other features: pause and stop;The sound tip;The lock parameters;Fast forward and retreat quickly;
        • State signal output: 1 road stop state, 1 state road direction;
        • Control signal input: 1 way down along the priming, 1 way down along the trigger to stop;
        • communication interface: RS485, MODBUS protocol;
        • Applicable power: AC100-240 v / 20 w;
        • working temperature: 5 to 40 ℃;
        • Relative humidity: < 80% RH;
        • Dimension: 290 * 205 * 180 mm
        • Weight: 4.4 kg

        ACCESSORIES

        VIDEOS

        DOCUMENTATION

        DOWNLOAD

        REQUEST A QUOTE

        Specifications

        blogs

        BLOGS

        ABOUT US

        ABOUT US

        CONTACT US

        CONTACT US

        SERVICE CENTER

        SERVICE CENTER

        • ABOUT
        • |
        • PRODUCTS
        • |
        • CATALOGS
        • |
        • SUPPORT
        • |
        • SERVICE CENTER
        • |
        • CUSTOMERS
        • |
        • TERMS
        • |
        • Privacy Policy
        • |
        • FAQ
        • |
        • BLOGS

        [email protected], + 972-3-5595252
        ISRAEL: Hagavish 3 Holon
        UK: Cavendish House Parkway, Harlow Business Park, Harlow, CM19 5QF

        • Bsmart בניית אתרים
        • SAP
        altImg

        • Fully Supported on Chromee*
        • Color Blind Adjusted
        • Heavy Vision Adjusted
        • Regular Display
        • Access Keys MenuAlt + 0
        • Stop Motion
        • Remove Underline Links
        • Press Keys For View Resize
        • Ctrl + Larger
        • Ctrl - Smaller
        • Ctrl 0 Reset Size
        • Enable Disable Keyboard Focusing
        • Reset All To Defualt

        Access Keys

        • Enable/Disable This MenuAlt + 0
        • Skip To Main MenuAlt + 1
        • Skip To Main ContentAlt + 2
        • דלג למפת אתר מונגשת Alt + Shift + 3
        • SearchAlt + 4
        • Contact PageAlt + 7
        • דלג למפת העמוד Alt+5
        • Skip To HomepageAlt + h
        • Skip To Accessibilty MenuAlt + m

        *Firefox users: Use Alt + Shiftnumber

        In order to move between elements, Press - Tabkey, To backtrack press, - Shift + Tab

      • Skip To Main Menu
      • Skip To Main Content
      • Skip To Accessbilty Menu
      • This website uses cookies for the purpose of ongoing and proper operation in accordance with the privacy policy